TOWARD PI®Yalkaid 100KHz Full-Range SS-OCT (YG-100Max)

100kHz speed full-range swept-source OCT for anterior and posterior

  • Full-Range wide-field Swept Source OCT
  • 15mm x 15mm Wide-field OCTA
  • Choroid OCTA with Quantification Parameters
  • HD Anterior Scan with Anterior OCTA
  • 15mm Scan depth anterior
Get a Quote
Product Details Image
Product Details Image

Redefine the basic requirements for OCT
Making all images and calculations meet the highest standards

Yalkaid (YG-100K) features a new generation SS-OCT with a remarkable speed of 100kHz. Its key advantage lies in the full-range SS technology, enabling a scan depth of 12 mm for the vitreous, retina, choroid, and an extraordinary 15 mm for the anterior. The device’s <6 micron optical resolution ensures detailed observation of both anterior and posterior structures.

With a wavelength of 1060 nm, Yalkaid is particularly beneficial for scanning patients with cataracts and vitreous opacities. Its invisible character minimizes fixation distractions. Moreover, its extensive 17 mm line scans and 15 mm 3D/OCTA scans cover a larger area compared to traditional SD or SS-OCTs.

Yalkaid is equipped with a wide range of quantification and analysis tools that greatly assist in clinical practice and research. These features enhance diagnostic precision and contribute to better patient outcomes.

High-Performance OCT Advance your fast-paced practice

When you need an OCT with impeccable functionality for both anterior and osterior segments, Yalkaid is neearly the best choice . suitable for ophthalmologists of all professional specialties.

  • Superior scanning depth: offer12mm depth for posterior segments(cvering vitreous,retina,choroid)
  • 15mm for anterior segments for surpassing the 2-3 mm of traditional SD-OCT
  • Supports up to 17mm line scans and 15 mm 3D/OCTA scans
  • Utilizes a 1060nm wavelength for enhanced penetration through cataracts or vitreous opacities.
  • In-built AI Segmentation
Download Brochure

Performance OCT — faster, wider, with a new level of detail

Greater detail: See deeper instantly, with high-definition widefield imaging.
• 15×15 mm single-shot OCTA cube scan in addition to 12x12,8×8, 6×6 and 3×3 mm scans.
• Exclusive algorithm in the world, reveal the truth of choroid.
( Choroid Vessel Index (3D-CVI) / Choroid Vessel Density(2D) / Choroid Vessel Volume ratio (CVV/a) / Choroidal Stroma Index (CSI) / Choroidal Stroma Volume ratio (CSV/a) )

Product Details Image
Product Details Image
Top: Brand-New Choroid OCTA with Quantification Parameters
Left: Yalkaid OCTA 15mmx15mm

Comprehensive Methods for Glaucoma

The 3D optic disc analysis is a combination of RNFL thickness analysis and ONH parameters analysis.
Ganglion cell complex thickness is defined by the distance from internal limiting membrane (ILM) to outer inner plexiform layer IPL, which composes the inner 3 layers of the retina (NFL, ganglion cell layer (GCL) and inner plexiform layer). Each of these three layers is affected in glaucoma.

Product Details Image
Product Details Image

Nerve fiber & Peripapillary capillary

Because the Yalkaid scan covers a wide range, the en face image can clearly show the retinal NFL, aiding in the diagnosis of early glaucoma.

Nerve Fiber Layer in the book
Resolution Box Image
This en face image shows the nerve fiber layer slab
Resolution Box Image This en face image shows the nerve fiber layer slab

Images you must have seen

Full Range SS-OCT Images – impressive, convincing, simply sharp

Crystal Clear Image

BRVO (12 × 12 mm OCTA)

Crystal Clear Image

Diabetic Retinopathy(12×12mm OCTA)n

Crystal Clear Image

Full Range anterior scan-Cataract

Crystal Clear Image

Full Range anterior scan-ICL

Crystal Clear Image

High Myopia

Crystal Clear Image

ICL

Crystal Clear Image

IOL

Crystal Clear Image

Retinal detachment and macular hole

Crystal Clear Image

3D anterior scan

Crystal Clear Image

Vitreomacular traction 3D

How Yalkaid OCT works

Learn how OCT operates in our video.
Yalkaid YG-100K MAX

Compare Yalkaid and others OCT

Comapre the largest Normal OCT brands on the market. For more information ,please contact us.

  • A-scan Speed
  • Max. OCTA size
  • Max. Depth Anterior
  • Tracking speed
Product Details Image

Yalkaid (YG100K-MAX)

  • 100,000Hz
  • 15x15mm (HD)
  • 14mm
  • 128Hz
Product Details Image

Normal OCT

  • 68,000 - 100,000Hz
  • 12x12mm (HD)
  • 2.3-5.3 mm
  • 20-24Hz

Technical Data

OCT Model:YG-400K

OCT optical source
Swept Source
Center wavelength
1060nm
Scan speed
100,000 A-scans/sec
Max. Length (posterior)
17mm
Scan depth (anterior)
15mm
Axial best digital resolution
1.9μm
Fundus Imaging Methodology
Line-scanning ophthalmoscope (LSO)
Eye tracking speed
100Hz
LSO FOV
40° ×40°
Minimum pupil diameter
2.0mm
Max. Single scan size (anterior)
18mm×18mm
Max. Single scan size (posterior)
15mm×15mm
Maximum resolution (single scan)
1024×1024
Software Functions

Look for reliable eye diagnostic instruments? Our team is here to help.

Get expert guidance and support to choose the right instruments for your practice.

Contact Us
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.