MOPTIM®Colombo IOL (Myopia Management 兒童近視管理)

The world's only OCT biometry device specifically designed for myopia control and management.

  • Measures parameters: AXL,CCT,K,ACD,LT,WTW,RT,PD,Optional:Choroidal Thickness
  • Simultaneous high-definition imaging of both the anterior and posterior segments of the eye
  • OCT report to aid in pre-surgical screening and decision-making
  • All in one design, no extra PC needed
Get a Quote
Product Details Image
Product Details Image

The Colombo is the first and only optical biometer
provides 4 mm real-time OCT imaging of the cornea and retina simultaneously during the acquisition

Based on the PCT patented technology, the Colombo IOL is the first and only optical biometer that provides 4 mm real-time OCT imaging of the cornea and retina simultaneously during the acquisition, which allows real-time fixation check, retinal screening, and choroidal thickness analysis.

The Colombo IOL measures up to 8 parameters in a single scan, including AXL, CCT, keratometry, ACD, WTW, pupil size, RT (retinal thickness), SFChT (subfoveal choroidal thickness).

 

B-scan Dual-path SD-OCT Biometry

The Colombo is a revolutionary B-scan optical biometer. Unlike the traditional A-scan optical biometer that only involves a one dimensional examination of the eye, the Colombo directs two independent optical paths to scan the cornea and retina separately, so the scans on cornea and retina could be optimized separately. As a result, it is possible to get 4mm corneal and retinal imaging during the acquistion.

  • Automatic Real-time Fixation Check
  • Myopia Progression Analysis
  • Choroidal Thickness Analysis*
Download Brochure

The New Gold Standard of Myopia Management

Getting Started
Example: 7 yrs, male RX=0.00D, VA=1.0 AXL=23.73 mm AXL/CR=2.85

Product Details Image
Product Details Image
Top: Progression analysis See the change of AXL before and during the treatment
Left: Reference interval of hyperopia reserve

DEFINITION OF AXIAL LENGTH

Correct fixation is the key to accurate AXL measurement. However, since children are less cooperative, it is more likely to get fixation loss. The Colombo IOL provides auto- matic real-time fixation check, as a result, incorrect measurements caused by unde- tected poor fixation will be eliminated automatically to ensure the measurements are consistently repeatable.
Axial length is the distance between the central anterior surface of the cornea and ILM at the fovea.

Product Details Image
Product Details Image

MORE THAN AN OPTICAL BIOMETER
The ONLY optical biometer that can measure choroidal thickness

Studies have found that choroids are thinner in longer, more myopic young adult eyes[2]. The findings suggest that choroidal thickness should be evaluated in myopia management. The Colombo IOL provides HD OCT images and measurement of SFChT for deep study in choroidal layer in myopic eyes. Myopic children have significantly thinner choroids compared to nonmyopic children of similar age, particularly in central foveal regions. The magnitude of difference in choroidal thickness associated with myopia appears greater than would be predicted by a simple passive choroidal thinning with axial elongation. Scott A. Read, Michael J. Collins, Stephen J. Vincent, David Alonso-Caneiro; Choroidal Thickness in Myopic and Nonmyopic Children Assessed With Enhanced Depth Imaging Optical Coherence Tomography. Invest. Ophthalmol. Vis. Sci. 2013;54(12):7578-7586. doi: https://doi.org/10.1167/iovs.13-12772.

Choroidal Thickness Analysis
Resolution Box Image Choroidal thickness: from outer edge of the hyper-reflective retinal pigment epithelial line to the inner edge of the sclera
COLOMBO vs. IOL Master 500
Resolution Box Image COLOMBO vs. IOL Master 500

Image gallery

How the MOPTIM®Colombo IOL works

Myopia Management 兒童近視管理

Technical Data

Biometer Model: Colombo IOL

OCT optical source
SD-OCT
Axial Length
12.1 mm – 38.0mm
Corneal Thickness
0.2 mm – 1.4 mm
Anterior Chamber Depth
0.7 mm – 6.0 mm
Pupil Size
0.5 mm – 13.5 mm
White-to-white
6mm – 16 mm
Resolution
5 μm
Imaging Capability
Real-time, simultaneously corneal and retinal imaging
Scan Range
4 mm
Dimension
527 (L) x 345 (W) x 507 (H) mm
Weight
19.7 kg
LCD Screen
10.1 inch touch screen (HDMI output available)
Power
220V~, 50Hz